Inhouse product
Why Buy From us?
Network cables are the most commonly used transmission mediums in generic cabling system. It is usually composed of 4 pairs of twisted wires and is generally applied in system cabling within 100 meters.
| Conductor | |
|---|---|
| Conductor Material | Oxygen free copper (99.97% purity) |
| Conductor Diameter | 0.52 mm ± 0.02 mm |
| Conductor American Wire Gauge | 24 AWG |
| Insulation | |
| Insulation Material | HDPE |
| Insulation Diameter | 0.92 mm ± 0.02 mm |
| Insulation Color (4 Pairs) | Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
| Separator | |
| Separator Material | PE |
| Separator Specification | Translucent 4.3 × 0.35 mm |
| Rip Cord | |
| Cord Material | Nylon |
| Cord Specification | 450D |
| Sheath | |
| Sheath Material | FR-PVC |
| Sheath Min. Average Thickness | 0.5 mm |
| Sheath Diameter | 5.8 mm ± 0.2 mm |
| Sheath Color | Blue |
| Electrical | |
| Cable Max. DC Resistance of a Single Conductor(+20℃) | 9Ω/100 m |
| Cable Min. Insulation Resistance | 5000MΩ·km |
| Cable Max. DC Resistance Unbalance | 2% (pair intra), 4% (pairs inter) |
| Cable Dielectric Strength | No breakdown with 1KV DC for 1 min |
| Transmission | |
| Cable Characteristic Impedance | 100 ± 15Ω |
| Cable Near End Cross Talk | ≥39.30 dB/100 m@250 MHz |
| Cable Max. Attenuation | 34.8 dB/100 m@250 MHz |
| Cable Return Loss | ≥17.3 dB/100 m@250 MHz |
| Mechanical | |
| Cable Tensile Strength | Sheath≥13.5 MPa, insulation≥16 MPa |
| Cable Elongation at Break | Sheath≥150%, insulation≥300% |
| Cable Installation Bending Radius | >8 times of outer cable diameter |
| Cable Conductor Elongation at Break | ≥10% |
| Environmental | |
| Cable Shrinkage of Insulation | ≤5% |
| Cable Color Migration Resistance of Insulation | No migration |
| Cable Sheath Tensile Strength and Elongation at Break after Aging | ≥12.5 MPa, ≥100% |
| Cable Low Temperature Bending Test | No cracking after the test |
| Cable Heat Shock Test | No cracking after the test |
| Cable Operating Temperature | –20°C to +60°C (–4°F to 140°F) |
| Cable Installation Temperature | 0°C to +50°C (32°F to 122°F) |
| Cable Storage Temperature and Humidity | –10°C to +40°C (14°F to 104°F), <60% (RH) |
| Security | |
| Cable Vertical Fire Propagation Test | Comply with IEC 60332-1-2 |
| Packaging | |
| Cable Cable Length | 305.0 m± 1.5 m |
| Cable Inner Carton Dimensions | 416*412*220mm(L × W × H) |
| Cable Protective Box Dimensions | 467*437*441mm(L × W × H) |
| Cable Packaging Method | 305.0 m per carton, 2 cartons in 1 protective box |
| Cable Net Weight | 10.8 kg |
| Cable Gross Weight | 11.6 kg |
| Compliance | |
| Cable Executive Standards | Q/DXJ 067-2019,EN50575-2014 |